33. 

Two resistors R1 = 36 Ω ± 5% and R2 = 75 Ω ± 5% are connected in series. The total resistance is

A. 111 ± 0 Ω
B. 111 ± 2.778 Ω
C. 111 ± 5.55 Ω
D. 111 ± 7.23 Ω

Answer: Option C

Explanation:

254-319-1

Total maximum error ± (1.8 + 3.75) = ± 5.55 Ω.

View Answer Discuss Workspace Report

34. 

In a ballistic galvanometer, a charge of 100 μC gives a first swing of 25°. The charge required to cause first swing of 50° is

A. 200 μC
B. 400 μC
C. 50 μC
D. 25 μC

Answer: Option B

Explanation:

swing is proportional to charge.

View Answer Discuss Workspace Report

35. 

In figure, Z1 = 200∠60° Ω, Z2 = 400∠ - 90° Ω, Z3 = 300∠0°. Then Z4 for bridge to be balanced is

240-246-1

A. 150∠30° Ω
B. 400∠ - 90° Ω
C. 300∠90° Ω
D. 600∠ - 150° Ω

Answer: Option D

Explanation:

254-246-1

254-246-2

View Answer Discuss Workspace Report

36. 

As per BIS there are 6 accuracy classes of instruments.

A. True
B. False

Answer: Option B

Explanation:

There are 8 classes of accuracy as per BIS.

View Answer Discuss Workspace Report

37. 

Assertion (A): When a wattmeter is used for low impedance loads, the pressure coil is connected across the load.

Reason (R): A wattmeter measures apparent power.

A. Both A and R are true and R is correct explanation of A
B. Both A and R are true but R is not correct explanation of A
C. A is true R is false
D. A is false R is true

Answer: Option C

Explanation:

Wattmeter measures active power.

View Answer Discuss Workspace Report

38. 

An LVDT is used to measure displacement. The LVDT feeds a Voltmeter of 0-5 V range through a 250 gain amplifier. For a displacement 0.5 mm the output of LVDT is 2 mV. The sensitivity of instrument is

A. 0.1 V/mm
B. 0.5 V/mm
C. 1 V/mm
D. 5 V/mm

Answer: Option C

Explanation:

Final output = 2 x 10-3 x 250 = 0.5 V.

254-322-1

View Answer Discuss Workspace Report

39. 

A piezoelectric force transducer has a charge sensitivity of 20 pC/N. It is connected to a charge amplifier and overall gain of transducer and amplifier is 50 mV/N. The gain of amplifier is

A. 1 mV/pC
B. 1.5 mV/pC
C. 2.5 mV/pC
D. 4 mV/pC

Answer: Option C

Explanation:

254-267-1

View Answer Discuss Workspace Report

40. 

A moving coil instrument has a resistance of 0.6 Ω and full scale deflection at 0.1 A. To convert it into an ammeter of 0-15 A range, the resistance of shunt should be

A. 0.6 Ω
B. 0.06 Ω
C. 0.1 Ω
D. 0.004 Ω

Answer: Option D

Explanation:

252-26-1

View Answer Discuss Workspace Report

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

Questions & Answers

Aptitude Chemical Engineering Civil Engineering Computer Science & Engineering Current Affairs Data Interpretation Electrical & Electronics Engineering Electronics & Communication Engineering General Knowledge Logical Reasoning Mechanical Engineering Non Verbal Reasoning Verbal Ability Verbal Reasoning

Interviews

HR Interview

Jobs

Sarkari Jobs

Results

Rojgar ResultSarkari Result

Admission

Admission 2023

Admit Card

Admit Card 2023

Answer Key

Answer Key 2023
copyright
Privacy Policy
© 2025 IndiaBIX. All Rights Reserved.

Report